Curriculum
- 7 Sections
- 105 Lessons
- 65 Weeks
Expand all sectionsCollapse all sections
- Understanding IFE Level 4 Certificate in Fire Safety1
- Fire Safety and Fire Engineering Principles21
- 2.1Passive Fire Safety
- 2.2Active Fire Safety
- 2.3Pressurisation
- 2.4Leakage Paths
- 2.5Automatic Suppression Systems
- 2.6Smoke Control and Air Handling
- 2.7Compartmentation
- 2.8Fire Detection and Warning Systems
- 2.9Design Fire Size
- 2.10Smoke Movement
- 2.11ASET/RSET and factors that affect different phases of evacuation
- 2.12Fire Resistance
- 2.13Fire Load
- 2.14Fire Growth
- 2.15Limit of Tenability
- 2.16t² Growth Rate
- 2.17Zone and Fire Models
- 2.18Use of flow chart to support design process
- 2.19Fire/Smoke modelling, examples of programmes
- 2.20Pedestrian flow/evacuation modelling
- 2.21Quiz 1 – Fire Safety and Fire Engineering Principles5 Questions
- Human Behaviour in Emergency Situations10
- 3.1Interaction between Fire safety systems and Human behaviour
- 3.2The physiological, behavioural and psychological effects on people confronted by a fire situation
- 3.3How behaviour of people in a fire can adversely affect evacuation and means of escape
- 3.4Emergency procedures for the safe evacuation of people from a fire situation
- 3.5Individuals with particular requirements to include the young, the old, the disabled, those with poor health, short term and long-term conditions, cognitive impairment and people from different cultures
- 3.6Behavioural aspects of people in fire and implications when planning/reviewing means of escape and evacuation procedures
- 3.7Major incidents of Note
- 3.8Identification of patterns and application of learning from previous incidents
- 3.9Case Study – Grenfell Tower
- 3.10Quiz 2 – Human Behaviour in Emergency Situations5 Questions
- Fire Protection Equipment18
- 4.1Types of System
- 4.2Success or Failure of Operation
- 4.3Automatic Fire Detectors – Radio Systems
- 4.4Automatic Fire Detection – Detector Circuits
- 4.5Zones, addressable for complex evacuation strategies, double knock, multi-purpose detectors
- 4.6Aspirating systems
- 4.7Control and Indicating Equipment
- 4.8Sprinkler systems: Commercial, Residential, and Domestic (life safety)
- 4.9Other water- based systems, drenchers, foam, water mist
- 4.10Gaseous Systems
- 4.11Oxygen Depletion Systems
- 4.12Explosion Detection Systems
- 4.13Explosion Venting Systems
- 4.14Explosion Suppression Systems
- 4.15Control of Flammable Atmospheres
- 4.16Fire Curtains
- 4.17Shutters
- 4.18Quiz 3 – Fire Protection Equipment5 Questions
- Building Design37
- 5.1Evaluate plans to identify risk and provide fire safety solutions
- 5.2Applied Protection
- 5.3Modern Methods of Construction
- 5.4Cross Laminated Timber
- 5.5Steel Frame
- 5.6Glulam
- 5.7Large structural timber
- 5.8Structural Insulated Panels
- 5.9Modular Construction
- 5.10Fire retardant, Intumescent treatments
- 5.11Upgrading fire resisting doors
- 5.12Atria
- 5.13Glazing
- 5.14Separating Walls
- 5.15Compartment Walls and Floors
- 5.16Junctions Formed by Elements of Structure
- 5.17Protected Shafts and Protecting Structures
- 5.18Fire Resisting Doors and Other Enclosures
- 5.19Claddings
- 5.20Facades
- 5.21Tunnels
- 5.22Heating Systems
- 5.23Ventilation
- 5.24Air Conditioning Systems
- 5.25Stairwell Pressurisation Systems
- 5.26Ventilation and Smoke Handling Systems
- 5.27Lifts/Elevators
- 5.28Escalators
- 5.29Travellators
- 5.30Consultation Process
- 5.31Qualitative Design Review (QDR)
- 5.32Interaction and Compatibility Between Different Materials
- 5.33Unexpected consequences of Inappropriate Selection, Use, Location, Orientation and Interaction of Materials
- 5.34Impact of Quality of Construction
- 5.35Impact of Modern Methods of Construction
- 5.36During Construction and Alterations
- 5.37Quiz 4 – Building Design5 Questions
- Fire Safety Management, Review and Advice22
- 6.1Principles and methods of risk assessment in Complex premises and Environments
- 6.2Impact of structure, materials and access
- 6.3Identification of people who may be at risk
- 6.4Identification of risks to Property and the Environment
- 6.5How to explain risks to Members of the Public and Property owners/managers
- 6.6Common causes of Fire in Different Occupancies
- 6.7How to Review Effectiveness of Current Measures
- 6.8How to provide Feedback on Effectiveness of Current measures
- 6.9Impact of Organisational Constraints
- 6.10Strategic thinking
- 6.11The Use of Fire Statistics to Inform Decisions on Fire Safety Programmes
- 6.12Risks in the Community and Prioritising Fire Safety Programmes
- 6.13Objectives of Fire Safety Education in the Community
- 6.14Contents of Fire Safety Programmes and their Purpose
- 6.15Methods to Engage Diverse Community Members and Stakeholders
- 6.16Methods to Evaluate Success of Programmes
- 6.17Strategic Thinking
- 6.18Level of Fire Safety Knowledge and Responsibility at Different parts of the Organisation
- 6.19Engaging and Training Employees in Different Premises/Workplaces and in Different roles
- 6.20Identification of Training Requirements for People with Fire Safety Responsibility
- 6.21Importance of Testing and Reviewing Precautions in Place and how to do this
- 6.22Quiz 5 – Fire Safety Management, Review and Advice5 Questions
- Preparing & Booking for Exams1
Control and Indicating Equipment
Control and Indicating Equipment
Control and Indicating Equipment (often abbreviated as CIE) forms the central nervous system of a fire alarm system, playing a pivotal role in managing, monitoring, and communicating fire detection and safety responses within a building. This equipment typically includes the fire alarm control panel (FACP), interfaces, and display units that receive signals from detectors and manual call points, process these inputs, and initiate appropriate alarm or safety measures. Understanding the function, components, and importance of control and indicating equipment is essential for ensuring reliable fire detection and effective emergency response.
A key feature of control and indicating equipment is its ability to provide clear, immediate information about the fire’s location and the system’s status. Modern control panels often incorporate graphic displays or LED indicators that identify which detector or zone has been activated. This rapid identification supports quicker decision-making by fire wardens, building managers, and emergency responders, helping them to locate the fire promptly and coordinate evacuation or firefighting efforts. In more complex addressable systems, the control equipment can pinpoint the exact device that triggered the alarm, improving response accuracy even further.
Control panels vary in complexity, from simple conventional panels suitable for small buildings to sophisticated addressable panels designed for large or multi-site installations. Advanced panels offer programmability, allowing customisation of alarm responses, integration with other building management systems, and the use of features such as phased evacuation or voice evacuation messages. Some control and indicating equipment also includes remote monitoring capabilities, enabling off-site surveillance by fire safety professionals or monitoring centres, which can alert emergency services even if no one is present in the building.
Reliability and compliance with standards are critical for control and indicating equipment. These systems must be robust, with backup power supplies such as batteries or generators to ensure operation during power outages.
They also need to be regularly tested and maintained to verify functionality and prevent failures. Control panels are designed to detect faults in the wiring, devices, or power supplies and alert maintenance personnel before a failure compromises fire safety.
Beyond fire detection, control and indicating equipment may interface with other safety systems to manage complex emergency scenarios.
For example, they can control door releases, activate smoke control fans, or trigger emergency shutdown procedures for hazardous processes. This integration enables coordinated and automatic responses that can limit fire spread, protect escape routes, and safeguard critical infrastructure.
User interface design is also an important consideration. Control panels must be intuitive and easy to operate, especially during high-stress fire situations. Clear visual and audible signals, simple controls, and straightforward fault diagnosis features assist trained personnel in managing the fire alarm system efficiently.
Training for building staff on using control and indicating equipment is therefore essential to ensure that alarms are acknowledged, faults addressed promptly, and emergency procedures enacted correctly.
Control and indicating equipment is the vital hub that brings together all elements of a fire alarm system, enabling timely detection, clear communication, and effective management of fire emergencies.
Its design and functionality directly impact the overall performance of fire safety measures and occupant protection. Through careful selection, installation, maintenance, and user training, control and indicating equipment can provide reliable early warning and support coordinated emergency responses, significantly reducing the risks associated with fire incidents.