Curriculum
- 7 Sections
- 105 Lessons
- 65 Weeks
Expand all sectionsCollapse all sections
- Understanding IFE Level 4 Certificate in Fire Safety1
- Fire Safety and Fire Engineering Principles21
- 2.1Passive Fire Safety
- 2.2Active Fire Safety
- 2.3Pressurisation
- 2.4Leakage Paths
- 2.5Automatic Suppression Systems
- 2.6Smoke Control and Air Handling
- 2.7Compartmentation
- 2.8Fire Detection and Warning Systems
- 2.9Design Fire Size
- 2.10Smoke Movement
- 2.11ASET/RSET and factors that affect different phases of evacuation
- 2.12Fire Resistance
- 2.13Fire Load
- 2.14Fire Growth
- 2.15Limit of Tenability
- 2.16t² Growth Rate
- 2.17Zone and Fire Models
- 2.18Use of flow chart to support design process
- 2.19Fire/Smoke modelling, examples of programmes
- 2.20Pedestrian flow/evacuation modelling
- 2.21Quiz 1 – Fire Safety and Fire Engineering Principles5 Questions
- Human Behaviour in Emergency Situations10
- 3.1Interaction between Fire safety systems and Human behaviour
- 3.2The physiological, behavioural and psychological effects on people confronted by a fire situation
- 3.3How behaviour of people in a fire can adversely affect evacuation and means of escape
- 3.4Emergency procedures for the safe evacuation of people from a fire situation
- 3.5Individuals with particular requirements to include the young, the old, the disabled, those with poor health, short term and long-term conditions, cognitive impairment and people from different cultures
- 3.6Behavioural aspects of people in fire and implications when planning/reviewing means of escape and evacuation procedures
- 3.7Major incidents of Note
- 3.8Identification of patterns and application of learning from previous incidents
- 3.9Case Study – Grenfell Tower
- 3.10Quiz 2 – Human Behaviour in Emergency Situations5 Questions
- Fire Protection Equipment18
- 4.1Types of System
- 4.2Success or Failure of Operation
- 4.3Automatic Fire Detectors – Radio Systems
- 4.4Automatic Fire Detection – Detector Circuits
- 4.5Zones, addressable for complex evacuation strategies, double knock, multi-purpose detectors
- 4.6Aspirating systems
- 4.7Control and Indicating Equipment
- 4.8Sprinkler systems: Commercial, Residential, and Domestic (life safety)
- 4.9Other water- based systems, drenchers, foam, water mist
- 4.10Gaseous Systems
- 4.11Oxygen Depletion Systems
- 4.12Explosion Detection Systems
- 4.13Explosion Venting Systems
- 4.14Explosion Suppression Systems
- 4.15Control of Flammable Atmospheres
- 4.16Fire Curtains
- 4.17Shutters
- 4.18Quiz 3 – Fire Protection Equipment5 Questions
- Building Design37
- 5.1Evaluate plans to identify risk and provide fire safety solutions
- 5.2Applied Protection
- 5.3Modern Methods of Construction
- 5.4Cross Laminated Timber
- 5.5Steel Frame
- 5.6Glulam
- 5.7Large structural timber
- 5.8Structural Insulated Panels
- 5.9Modular Construction
- 5.10Fire retardant, Intumescent treatments
- 5.11Upgrading fire resisting doors
- 5.12Atria
- 5.13Glazing
- 5.14Separating Walls
- 5.15Compartment Walls and Floors
- 5.16Junctions Formed by Elements of Structure
- 5.17Protected Shafts and Protecting Structures
- 5.18Fire Resisting Doors and Other Enclosures
- 5.19Claddings
- 5.20Facades
- 5.21Tunnels
- 5.22Heating Systems
- 5.23Ventilation
- 5.24Air Conditioning Systems
- 5.25Stairwell Pressurisation Systems
- 5.26Ventilation and Smoke Handling Systems
- 5.27Lifts/Elevators
- 5.28Escalators
- 5.29Travellators
- 5.30Consultation Process
- 5.31Qualitative Design Review (QDR)
- 5.32Interaction and Compatibility Between Different Materials
- 5.33Unexpected consequences of Inappropriate Selection, Use, Location, Orientation and Interaction of Materials
- 5.34Impact of Quality of Construction
- 5.35Impact of Modern Methods of Construction
- 5.36During Construction and Alterations
- 5.37Quiz 4 – Building Design5 Questions
- Fire Safety Management, Review and Advice22
- 6.1Principles and methods of risk assessment in Complex premises and Environments
- 6.2Impact of structure, materials and access
- 6.3Identification of people who may be at risk
- 6.4Identification of risks to Property and the Environment
- 6.5How to explain risks to Members of the Public and Property owners/managers
- 6.6Common causes of Fire in Different Occupancies
- 6.7How to Review Effectiveness of Current Measures
- 6.8How to provide Feedback on Effectiveness of Current measures
- 6.9Impact of Organisational Constraints
- 6.10Strategic thinking
- 6.11The Use of Fire Statistics to Inform Decisions on Fire Safety Programmes
- 6.12Risks in the Community and Prioritising Fire Safety Programmes
- 6.13Objectives of Fire Safety Education in the Community
- 6.14Contents of Fire Safety Programmes and their Purpose
- 6.15Methods to Engage Diverse Community Members and Stakeholders
- 6.16Methods to Evaluate Success of Programmes
- 6.17Strategic Thinking
- 6.18Level of Fire Safety Knowledge and Responsibility at Different parts of the Organisation
- 6.19Engaging and Training Employees in Different Premises/Workplaces and in Different roles
- 6.20Identification of Training Requirements for People with Fire Safety Responsibility
- 6.21Importance of Testing and Reviewing Precautions in Place and how to do this
- 6.22Quiz 5 – Fire Safety Management, Review and Advice5 Questions
- Preparing & Booking for Exams1
During Construction and Alterations
During Construction and Alterations
During construction and alterations, the risk of fire and the potential compromise of fire safety measures are significantly increased. This phase of a building’s lifecycle is inherently vulnerable because many of the permanent fire protection systems may not yet be operational or fully installed, and the environment is often dynamic, with temporary structures, exposed services, and high-risk activities such as welding or hot works taking place. Understanding and managing these risks is essential to maintaining fire safety throughout the construction process and ensuring that the finished building meets its intended fire performance.
most immediate concerns
One of the most immediate concerns during construction is the absence or incompleteness of passive fire protection features such as compartment walls, fire doors, and fire stopping. These elements are often installed late in the programme, which means that for extended periods, the building lacks the physical barriers needed to prevent fire and smoke from spreading. This makes the site more susceptible to rapid fire growth and uncontrolled spread, especially where combustible materials are stored or used.
risks
The risk is further heightened by the presence of flammable construction materials, temporary enclosures, and fuel sources such as gas cylinders, adhesives, and packaging. Inappropriate storage or handling of these materials can significantly increase fire load and create ignition sources, particularly when combined with hot works like grinding or soldering. Unless carefully managed, these operations can quickly lead to fire incidents.
Temporary electrical installations also pose a risk. Cabling, lighting, and equipment used during construction are sometimes poorly protected, overloaded, or exposed to damage, creating fire hazards. Faulty or makeshift electrical setups can be a source of ignition, particularly in areas with dust or combustible vapours.
During alterations or refurbishment, existing fire safety measures may be disrupted. Walls may be removed, fire doors propped open, or fire-stopping materials disturbed, all of which can undermine the integrity of fire compartments. If these elements are not properly reinstated, the building’s long-term fire performance may be compromised. Similarly, temporary fire safety systems—such as alarms, extinguishers, and escape signage—may be inadequate, incomplete, or poorly maintained during this period.
To manage these risks, fire safety must be incorporated into the construction management plan. This includes implementing a fire risk assessment specific to the site, monitoring hot works with permit-to-work systems, enforcing good housekeeping to prevent accumulation of combustible waste, and ensuring that temporary fire detection and evacuation procedures are in place and understood by all site personnel.
The construction and alteration phases present a critical window where fire safety must be actively managed to prevent incidents and ensure the integrity of the building’s final fire strategy. Temporary conditions, incomplete systems, and high-risk activities all require careful control, regular inspection, and a strong fire safety culture on site. Only by maintaining high standards throughout can the building ultimately deliver the level of protection it was designed to provide.