Curriculum
- 7 Sections
- 105 Lessons
- 65 Weeks
Expand all sectionsCollapse all sections
- Understanding IFE Level 4 Certificate in Fire Safety1
- Fire Safety and Fire Engineering Principles21
- 2.1Passive Fire Safety
- 2.2Active Fire Safety
- 2.3Pressurisation
- 2.4Leakage Paths
- 2.5Automatic Suppression Systems
- 2.6Smoke Control and Air Handling
- 2.7Compartmentation
- 2.8Fire Detection and Warning Systems
- 2.9Design Fire Size
- 2.10Smoke Movement
- 2.11ASET/RSET and factors that affect different phases of evacuation
- 2.12Fire Resistance
- 2.13Fire Load
- 2.14Fire Growth
- 2.15Limit of Tenability
- 2.16t² Growth Rate
- 2.17Zone and Fire Models
- 2.18Use of flow chart to support design process
- 2.19Fire/Smoke modelling, examples of programmes
- 2.20Pedestrian flow/evacuation modelling
- 2.21Quiz 1 – Fire Safety and Fire Engineering Principles5 Questions
- Human Behaviour in Emergency Situations10
- 3.1Interaction between Fire safety systems and Human behaviour
- 3.2The physiological, behavioural and psychological effects on people confronted by a fire situation
- 3.3How behaviour of people in a fire can adversely affect evacuation and means of escape
- 3.4Emergency procedures for the safe evacuation of people from a fire situation
- 3.5Individuals with particular requirements to include the young, the old, the disabled, those with poor health, short term and long-term conditions, cognitive impairment and people from different cultures
- 3.6Behavioural aspects of people in fire and implications when planning/reviewing means of escape and evacuation procedures
- 3.7Major incidents of Note
- 3.8Identification of patterns and application of learning from previous incidents
- 3.9Case Study – Grenfell Tower
- 3.10Quiz 2 – Human Behaviour in Emergency Situations5 Questions
- Fire Protection Equipment18
- 4.1Types of System
- 4.2Success or Failure of Operation
- 4.3Automatic Fire Detectors – Radio Systems
- 4.4Automatic Fire Detection – Detector Circuits
- 4.5Zones, addressable for complex evacuation strategies, double knock, multi-purpose detectors
- 4.6Aspirating systems
- 4.7Control and Indicating Equipment
- 4.8Sprinkler systems: Commercial, Residential, and Domestic (life safety)
- 4.9Other water- based systems, drenchers, foam, water mist
- 4.10Gaseous Systems
- 4.11Oxygen Depletion Systems
- 4.12Explosion Detection Systems
- 4.13Explosion Venting Systems
- 4.14Explosion Suppression Systems
- 4.15Control of Flammable Atmospheres
- 4.16Fire Curtains
- 4.17Shutters
- 4.18Quiz 3 – Fire Protection Equipment5 Questions
- Building Design37
- 5.1Evaluate plans to identify risk and provide fire safety solutions
- 5.2Applied Protection
- 5.3Modern Methods of Construction
- 5.4Cross Laminated Timber
- 5.5Steel Frame
- 5.6Glulam
- 5.7Large structural timber
- 5.8Structural Insulated Panels
- 5.9Modular Construction
- 5.10Fire retardant, Intumescent treatments
- 5.11Upgrading fire resisting doors
- 5.12Atria
- 5.13Glazing
- 5.14Separating Walls
- 5.15Compartment Walls and Floors
- 5.16Junctions Formed by Elements of Structure
- 5.17Protected Shafts and Protecting Structures
- 5.18Fire Resisting Doors and Other Enclosures
- 5.19Claddings
- 5.20Facades
- 5.21Tunnels
- 5.22Heating Systems
- 5.23Ventilation
- 5.24Air Conditioning Systems
- 5.25Stairwell Pressurisation Systems
- 5.26Ventilation and Smoke Handling Systems
- 5.27Lifts/Elevators
- 5.28Escalators
- 5.29Travellators
- 5.30Consultation Process
- 5.31Qualitative Design Review (QDR)
- 5.32Interaction and Compatibility Between Different Materials
- 5.33Unexpected consequences of Inappropriate Selection, Use, Location, Orientation and Interaction of Materials
- 5.34Impact of Quality of Construction
- 5.35Impact of Modern Methods of Construction
- 5.36During Construction and Alterations
- 5.37Quiz 4 – Building Design5 Questions
- Fire Safety Management, Review and Advice22
- 6.1Principles and methods of risk assessment in Complex premises and Environments
- 6.2Impact of structure, materials and access
- 6.3Identification of people who may be at risk
- 6.4Identification of risks to Property and the Environment
- 6.5How to explain risks to Members of the Public and Property owners/managers
- 6.6Common causes of Fire in Different Occupancies
- 6.7How to Review Effectiveness of Current Measures
- 6.8How to provide Feedback on Effectiveness of Current measures
- 6.9Impact of Organisational Constraints
- 6.10Strategic thinking
- 6.11The Use of Fire Statistics to Inform Decisions on Fire Safety Programmes
- 6.12Risks in the Community and Prioritising Fire Safety Programmes
- 6.13Objectives of Fire Safety Education in the Community
- 6.14Contents of Fire Safety Programmes and their Purpose
- 6.15Methods to Engage Diverse Community Members and Stakeholders
- 6.16Methods to Evaluate Success of Programmes
- 6.17Strategic Thinking
- 6.18Level of Fire Safety Knowledge and Responsibility at Different parts of the Organisation
- 6.19Engaging and Training Employees in Different Premises/Workplaces and in Different roles
- 6.20Identification of Training Requirements for People with Fire Safety Responsibility
- 6.21Importance of Testing and Reviewing Precautions in Place and how to do this
- 6.22Quiz 5 – Fire Safety Management, Review and Advice5 Questions
- Preparing & Booking for Exams1
Interaction between Fire safety systems and Human behaviour
Interaction between Fire safety systems and Human behaviour
The interaction between fire safety systems and human behaviour is a critical component in the successful management of fire safety within buildings and facilities. While technological systems are designed to detect, contain, and suppress fires, their effectiveness often depends on how individuals respond to them. Understanding this interaction allows for the design of safer environments that not only rely on engineering solutions but also anticipate and guide human actions in emergency situations
Fire safety systems, including alarms, smoke detectors, sprinklers, emergency lighting, and evacuation signage, are engineered to activate in specific ways during a fire incident. Their primary function is to provide early warning, suppress the fire where possible, and support safe evacuation. However, these systems do not operate in a vacuum. Human behaviour—both expected and unexpected—can significantly influence how effective these systems are in a real emergency. People might respond calmly and follow procedures, or they may panic, become confused, or act in ways that compromise their safety or the safety of others.
One of the most important aspects of this interaction is perception. Individuals must first recognise and interpret the cues provided by fire safety systems. An alarm sounding, for example, must be loud and distinct enough to capture attention, but also unambiguous in its meaning. If an alarm is too similar to other signals or if people are not trained to understand its significance, they may delay their response. This delay can be critical, particularly in fast-developing fires. Visual cues, such as flashing lights or signage, also play a role, especially in environments where auditory signals may not be effective, such as in noisy industrial settings or for people with hearing impairments.
Training and fire drills are key to bridging the gap between system functionality and human action. People who are familiar with fire safety systems and have practised evacuation procedures are more likely to respond promptly and appropriately. Conversely, in environments where training is lacking or drills are infrequent, people may hesitate, seek confirmation, or return for belongings, all of which can endanger lives. Familiarity breeds confidence and reduces the instinct to freeze or wait for others to act first. The design of fire safety systems must therefore consider not only the technical performance of equipment but also the ways in which people are prepared to interact with these systems under stress.
Another important consideration is the concept of wayfinding. In a fire emergency, individuals must be able to navigate safely and quickly to exits. Emergency lighting and signage are designed to assist with this, but human factors such as stress, disorientation due to smoke, or unfamiliarity with the building layout can severely impede effective evacuation. In complex buildings, simply having an exit sign may not be enough. Systems must be intuitive and resilient under adverse conditions, supporting instinctive responses rather than requiring rational thought, which may be impaired in a crisis.
Technological advances have introduced more intelligent systems that adapt to human behaviour in real time. For example, some fire alarm systems are now capable of providing voice instructions, which can help guide people more effectively than sirens alone. Dynamic signage that changes direction based on the location of the fire can prevent individuals from walking towards danger. These innovations highlight a growing recognition that fire safety is not just about detecting and fighting fire, but about influencing human decision-making in high-stress scenarios.
There is also a social dimension to consider. People do not act in isolation during a fire; group behaviour, social influence, and cultural norms can affect how individuals respond. In some cases, people may prioritise helping others over their own evacuation, or they may delay leaving to wait for colleagues or family members. Others may follow the crowd without assessing whether that path is safe. Fire safety systems and protocols must be designed with these tendencies in mind, encouraging efficient and safe group movement while minimising bottlenecks and confusion.
Fire Safety Management
Ultimately, the interaction between fire safety systems and human behaviour underscores the importance of a holistic approach to fire safety management. Systems must be designed not only to perform their mechanical function, but to complement and support human responses in emergencies. Regular training, clear communication, intuitive system design, and continuous evaluation of human factors all play a role in ensuring that fire safety systems fulfil their purpose when they are needed most. By integrating an understanding of how people react in fires with the capabilities of modern safety technologies, we can create environments that are both safer and more resilient.