Curriculum
- 7 Sections
- 105 Lessons
- 65 Weeks
Expand all sectionsCollapse all sections
- Understanding IFE Level 4 Certificate in Fire Safety1
- Fire Safety and Fire Engineering Principles21
- 2.1Passive Fire Safety
- 2.2Active Fire Safety
- 2.3Pressurisation
- 2.4Leakage Paths
- 2.5Automatic Suppression Systems
- 2.6Smoke Control and Air Handling
- 2.7Compartmentation
- 2.8Fire Detection and Warning Systems
- 2.9Design Fire Size
- 2.10Smoke Movement
- 2.11ASET/RSET and factors that affect different phases of evacuation
- 2.12Fire Resistance
- 2.13Fire Load
- 2.14Fire Growth
- 2.15Limit of Tenability
- 2.16t² Growth Rate
- 2.17Zone and Fire Models
- 2.18Use of flow chart to support design process
- 2.19Fire/Smoke modelling, examples of programmes
- 2.20Pedestrian flow/evacuation modelling
- 2.21Quiz 1 – Fire Safety and Fire Engineering Principles5 Questions
- Human Behaviour in Emergency Situations10
- 3.1Interaction between Fire safety systems and Human behaviour
- 3.2The physiological, behavioural and psychological effects on people confronted by a fire situation
- 3.3How behaviour of people in a fire can adversely affect evacuation and means of escape
- 3.4Emergency procedures for the safe evacuation of people from a fire situation
- 3.5Individuals with particular requirements to include the young, the old, the disabled, those with poor health, short term and long-term conditions, cognitive impairment and people from different cultures
- 3.6Behavioural aspects of people in fire and implications when planning/reviewing means of escape and evacuation procedures
- 3.7Major incidents of Note
- 3.8Identification of patterns and application of learning from previous incidents
- 3.9Case Study – Grenfell Tower
- 3.10Quiz 2 – Human Behaviour in Emergency Situations5 Questions
- Fire Protection Equipment18
- 4.1Types of System
- 4.2Success or Failure of Operation
- 4.3Automatic Fire Detectors – Radio Systems
- 4.4Automatic Fire Detection – Detector Circuits
- 4.5Zones, addressable for complex evacuation strategies, double knock, multi-purpose detectors
- 4.6Aspirating systems
- 4.7Control and Indicating Equipment
- 4.8Sprinkler systems: Commercial, Residential, and Domestic (life safety)
- 4.9Other water- based systems, drenchers, foam, water mist
- 4.10Gaseous Systems
- 4.11Oxygen Depletion Systems
- 4.12Explosion Detection Systems
- 4.13Explosion Venting Systems
- 4.14Explosion Suppression Systems
- 4.15Control of Flammable Atmospheres
- 4.16Fire Curtains
- 4.17Shutters
- 4.18Quiz 3 – Fire Protection Equipment5 Questions
- Building Design37
- 5.1Evaluate plans to identify risk and provide fire safety solutions
- 5.2Applied Protection
- 5.3Modern Methods of Construction
- 5.4Cross Laminated Timber
- 5.5Steel Frame
- 5.6Glulam
- 5.7Large structural timber
- 5.8Structural Insulated Panels
- 5.9Modular Construction
- 5.10Fire retardant, Intumescent treatments
- 5.11Upgrading fire resisting doors
- 5.12Atria
- 5.13Glazing
- 5.14Separating Walls
- 5.15Compartment Walls and Floors
- 5.16Junctions Formed by Elements of Structure
- 5.17Protected Shafts and Protecting Structures
- 5.18Fire Resisting Doors and Other Enclosures
- 5.19Claddings
- 5.20Facades
- 5.21Tunnels
- 5.22Heating Systems
- 5.23Ventilation
- 5.24Air Conditioning Systems
- 5.25Stairwell Pressurisation Systems
- 5.26Ventilation and Smoke Handling Systems
- 5.27Lifts/Elevators
- 5.28Escalators
- 5.29Travellators
- 5.30Consultation Process
- 5.31Qualitative Design Review (QDR)
- 5.32Interaction and Compatibility Between Different Materials
- 5.33Unexpected consequences of Inappropriate Selection, Use, Location, Orientation and Interaction of Materials
- 5.34Impact of Quality of Construction
- 5.35Impact of Modern Methods of Construction
- 5.36During Construction and Alterations
- 5.37Quiz 4 – Building Design5 Questions
- Fire Safety Management, Review and Advice22
- 6.1Principles and methods of risk assessment in Complex premises and Environments
- 6.2Impact of structure, materials and access
- 6.3Identification of people who may be at risk
- 6.4Identification of risks to Property and the Environment
- 6.5How to explain risks to Members of the Public and Property owners/managers
- 6.6Common causes of Fire in Different Occupancies
- 6.7How to Review Effectiveness of Current Measures
- 6.8How to provide Feedback on Effectiveness of Current measures
- 6.9Impact of Organisational Constraints
- 6.10Strategic thinking
- 6.11The Use of Fire Statistics to Inform Decisions on Fire Safety Programmes
- 6.12Risks in the Community and Prioritising Fire Safety Programmes
- 6.13Objectives of Fire Safety Education in the Community
- 6.14Contents of Fire Safety Programmes and their Purpose
- 6.15Methods to Engage Diverse Community Members and Stakeholders
- 6.16Methods to Evaluate Success of Programmes
- 6.17Strategic Thinking
- 6.18Level of Fire Safety Knowledge and Responsibility at Different parts of the Organisation
- 6.19Engaging and Training Employees in Different Premises/Workplaces and in Different roles
- 6.20Identification of Training Requirements for People with Fire Safety Responsibility
- 6.21Importance of Testing and Reviewing Precautions in Place and how to do this
- 6.22Quiz 5 – Fire Safety Management, Review and Advice5 Questions
- Preparing & Booking for Exams1
Qualitative Design Review (QDR)
Qualitative Design Review (QDR)
A Qualitative Design Review (QDR) is a structured evaluation process used in fire safety engineering and building design to assess the effectiveness and adequacy of proposed fire safety measures early in the design stage. Unlike purely quantitative assessments that rely on numerical calculations and simulations, a QDR focuses on the overall quality, appropriateness, and integration of fire safety strategies through expert judgement and qualitative analysis.
purpose of a QDR
The purpose of a QDR is to identify potential weaknesses or gaps in the fire safety design before detailed technical work begins, allowing for timely adjustments that can improve safety outcomes and ensure compliance with regulations. It involves a multidisciplinary team—often including fire engineers, architects, building control officers, and other relevant professionals—who review design documents, drawings, and concept proposals.
key elements
During the QDR, the team examines key elements such as means of escape, compartmentation, fire detection and alarm systems, suppression methods, smoke control, and access for firefighting. They consider whether these measures are suitably integrated with the building’s intended use, occupancy, size, and layout. The review also evaluates how well the design aligns with relevant building codes, standards, and best practice guidance.
A QDR encourages a holistic approach, looking beyond individual components to assess how different fire safety features interact and support each other.
For example, it may highlight if ventilation systems could inadvertently aid smoke spread or if escape routes are adequately protected and accessible. This process helps to ensure that fire safety is not treated as an isolated aspect but as an integral part of the overall building design.
The output of a Qualitative Design Review typically includes a report detailing observations, concerns, and recommendations for improvement. This report guides the design team in refining the fire safety strategy, reducing the risk of costly redesigns later and contributing to a safer building environment.
A Qualitative Design Review is a proactive, expert-led assessment focused on the quality and coherence of fire safety provisions in a building’s design. By identifying issues early and fostering collaboration among stakeholders, it plays a vital role in achieving effective and compliant fire safety solutions.